ACTIVE JOBS
6
4 drilling · 1 survey · 1 standby
TOOLS IN HOLE
6
All transmitting
FOOTAGE TODAY
1,847ft
Across all jobs
ALERTS
2
1 battery warn · 1 life warn
ALL ACTIVE JOBS
Hendricks 24-1H
Precision Drilling #187 · DC-2026-0847
10,242
MD (ft)
90.1°
INC
47
GR API
Castro Peak 12-2H
Patterson UTI #219 · DC-2026-0831
8,904
MD (ft)
88.7°
INC
52
GR API
Ward County 7-1H
Nabors #14 · DC-2026-0819
11,618
MD (ft)
90.3°
INC
39
GR API
Reagan North 4-3H
H&P #441 · DC-2026-0854
7,122
MD (ft)
44.2°
INC
61
GR API
Midland Basin 33-1H
Cactus Drilling #88 · DC-2026-0839
9,441
MD (ft)
90.0°
INC
44
GR API
Pecos Valley 9-2H
Pioneer Drilling #22 · DC-2026-0861
5,800
MD (ft)
0.4°
INC
—
GR API
| SERIAL # | ASSEMBLY / TYPE | CIRC HRS ↓ | REMAINING LIFE | LOCATION | LAST USED | INSPECT |
|---|
COMPONENT BREAKDOWN
| COMPONENT | SERIAL | RATED HRS | ACTUAL HRS | REMAINING | STATUS |
|---|
| SERIAL # | TYPE | MANUFACTURER | MFG DATE | TOTAL HRS | RATED HRS | REMAINING | CURRENT ASSEMBLY | STATUS |
|---|
ACTIVE BHA RUNS
6
All transmitting
ASSEMBLIES IN HOLE
30
5 per string × 6 jobs
WATCH / WARN
3
Assemblies below 30% life
CRITICAL
0
No assemblies below 10%
ACTIVE BHA STRINGS — click any assembly to view detail
Wire Harness Assembly — Batch W-2024-11 Recall
Potential insulation delamination on inner conductor wrap in batch W-2024-11 harnesses manufactured Oct–Nov 2024. Failure mode: intermittent short at elevated temp (>150°C). Do not run until inspected and cleared by shop supervisor.
Affected: Wire Harness · Batch W-2024-11 · SN range WH-44200 to WH-44380
2 IN SHOP · 0 IN FIELD
Plug End Seal O-Ring — Elevated Temp Compression Set
NBR o-rings on plug end assemblies shipped Q4 2025 showing early compression set in repeated high-temp cycles (>175°C). Inspect seal face for deformation before each run. Replace if any flat-spotting visible. HNBR upgrade available from supply.
Affected: Plug Ends · Q4 2025 production · All units with date code 25Q4
4 IN SHOP · 3 IN FIELD
Sensor Module Firmware — v2.1.443 Recommended Update
Firmware v2.1.443 improves GTF/MTF transition logic and reduces false toolface readings at low inclination (<3°). Recommended for all tools before next run. No field urgency — apply at next shop visit.
Affected: All APS SureShot sensor modules on firmware < v2.1.443
5 NEED UPDATE
RECEIVED REPORTS
Hendricks 24-1H
Castro Peak 12-2H
Ward County 7-1H
Reagan North 4-3H
Midland Basin 33-1H
DIRECTIONAL CONCEPTS INC.
MWD MORNING REPORT
────────────────────────────────────────────────────────
Well: Hendricks 24-1H Date: 2026-03-30
Rig: Precision Drilling #187 Time: 06:00 CST
Operator: Permian Basin Resources LLC Run: 2
────────────────────────────────────────────────────────
DEPTH SUMMARY
Depth BOR: 10,014 ft MD / 7,203.8 ft TVD
Depth EOR: 10,242 ft MD / 7,204.5 ft TVD
Footage Drilled: 228 ft
Avg ROP: 63.2 ft/hr
────────────────────────────────────────────────────────
SURVEYS
Last Survey: 10,242 ft MD
Inc / Az: 90.1° / 185.2°
DLS: 0.2°/100ft
────────────────────────────────────────────────────────
MWD / TOOL STATUS
Tool: APS SureShot SN: 40516
Battery 1: 74% — Est. EOL +18.2 hrs
Battery 2: 91% — Est. EOL +26.4 hrs
────────────────────────────────────────────────────────
Submitted by MWD — Directional Concepts Inc. DC-2026-0847
JOBS IN DB
47
Since 2024-06-01
AVG BATTERY ACTUAL
168hrs
Rated: 150 hrs · +12% better
FLEET UTILIZATION
67%
6 of 9 tools active
EARLY PULLS
8
Last 12 months — avoidable
BATTERY — ACTUAL vs RATED LIFE
47 jobs
TOOL LIFE REMAINING — FLEET
active tools
PREDICTIVE PULL POINTS — COMPONENT MODEL
| COMPONENT | RATED LIFE | HIST. ACTUAL AVG | DELTA | PRED. SAFE PULL | CONFIDENCE | JOBS (n) |
|---|---|---|---|---|---|---|
| MWD Barrel | 500 hrs | 524 hrs | +24 hrs | 512 hrs | ★★★★☆ High | 41 |
| Wire Harness | 10,000 hrs | 9,840 hrs | −160 hrs | 9,600 hrs | ★★☆☆☆ Low | 9 |
| Plug Ends | 5,000 hrs | 5,180 hrs | +180 hrs | 5,090 hrs | ★★★☆☆ Med | 22 |
| Sensor Module | 300 hrs | 318 hrs | +18 hrs | 308 hrs | ★★★★☆ High | 38 |
| UBHO | 2,000 hrs | 2,210 hrs | +210 hrs | 2,100 hrs | ★★★★★ V.High | 47 |
| Gamma Module | 1,000 hrs | 1,047 hrs | +47 hrs | 1,022 hrs | ★★★☆☆ Med | 19 |
MODEL NOTE: Predicted safe pull points update automatically as job data accumulates. Confidence rating is based on job count (n). Low confidence (<15 jobs) — treat as preliminary. High confidence (≥30 jobs) — suitable for policy. Wire Harness confidence is low; do not extend rated life until more data is available.
TOWN ASSISTANT
Ask anything about active jobs, tool inventory, life remaining, battery status, or fleet analytics. Answers come from live job data — not guesses.
How many active jobs within 20 miles of Midland?
What's life remaining on all tools in the field right now?
Which tools are due for shop inspection in the next 2 weeks?
What's our average actual vs. rated battery life over the last 30 jobs?
Which components are we consistently pulling too early?
Friday afternoon — what's the field looking like?
Which battery packs have exceeded their rated hours?
Show me all tools with life remaining below 30%.
TOTAL FAILURES (YTD)
7
IN-HOLE FAILURES
2
SHOP FAILURES
5
OPEN INVESTIGATIONS
3
CLOSED / RESOLVED
4
AVG HOURS AT FAILURE
287 hrs
FAILURE LOG
| DATE | COMPONENT SN | TYPE | ASSEMBLY | JOB # | HRS AT FAILURE | LOCATION | FAILURE MODE | ROOT CAUSE | STATUS |
|---|---|---|---|---|---|---|---|---|---|
| 2026-03-09 | SM-20711 | Sensor Module | 40243 | DC-2026-0819 | 312.1 | IN HOLE | Signal loss — intermittent | Under investigation | OPEN |
| 2026-02-14 | BR-40188 | 40188 | DC-2026-0791 | 498.3 | IN SHOP | Housing crack — pressure wash | End of rated life — normal wear | CLOSED | |
| 2026-01-28 | DC-1991 | DM Coil Assembly | DM-1991 | DC-2026-0774 | 241.7 | IN HOLE | Coil open — shock event | High shock — lateral section, Bone Spring | OPEN |
| 2026-01-11 | GC-7510 | Gamma Crystal | GR-7510 | DC-2025-0762 | 189.4 | IN SHOP | Crystal degraded — count drop 40% | Confirmed bad batch — see Tech Notice TN-2026-003 | CLOSED |
| 2025-12-19 | WH-43901 | Wire Harness | 40102 | DC-2025-0748 | 87.2 | IN SHOP | Open circuit — pin damage | Connection abuse — assembly error | OPEN |
FAILURE MODE BREAKDOWN (YTD)
SHOCK / VIBE
2
29% of failures
END OF LIFE
2
29% of failures
ASSEMBLY ERROR
1
14% of failures
BAD BATCH / MFG
1
14% of failures
UNDER INVESTIGATION
1
14% of failures
⚠ FAILURE ANALYSIS — STUB TAB · Structure and data model TBD · Full RCA workflow, MTBF trending, and component failure correlation planned
COMPANY
FIELD CONNECTIONS
MWD Suite 3000 instances relay data over Tailscale. Add each rig's Tailscale IP and port.
| JOB # | WELL | TAILSCALE HOST | PORT | STATUS |
|---|---|---|---|---|
| DC-2026-0847 | Hendricks 24-1H | 100.64.0.12 | 8085 | ● Connected |
| DC-2026-0831 | Castro Peak 12-2H | 100.64.0.18 | 8085 | ● Connected |
| DC-2026-0819 | Ward County 7-1H | 100.64.0.9 | 8085 | ● Connected |
TOOL LIFE THRESHOLDS
Set Watch / Warning / Critical thresholds per component type. All values are % remaining.
WATCH (%)
WARNING (%)
CRITICAL (%)
MWD Barrel
Sensor Module
Wire Harness
Plug Ends
UBHO
Gamma Module
NOTIFICATIONS
ABOUT
ApplicationMWD Town 3000
Version0.1.0-alpha
CompanionMWD Suite 3000 v0.1.0
StackPython / aiohttp / vanilla JS